{"id":2001,"date":"2014-01-22T10:34:52","date_gmt":"2014-01-22T10:34:52","guid":{"rendered":"https:\/\/te-instrumentation.nl\/ptfe-fep-kapton\/"},"modified":"2026-05-07T22:01:01","modified_gmt":"2026-05-07T21:01:01","slug":"ptfe-fep-kapton","status":"publish","type":"page","link":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/","title":{"rendered":"PTFE FEP Kapton"},"content":{"rendered":"<p><strong>TF\/TF<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-291\" alt=\"pro.wir.tef1\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef1_-300x9.jpg\" width=\"300\" height=\"9\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef1_-300x9.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef1_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Fused PTFE tape insulated conductors,\u00a0laid parallel and jacketed with fused PTFE tape<br \/>\n260\u00b0 C (500\u00b0F)<\/p>\n<p><strong>TEX\/TEX<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-299\" alt=\"pro.wir.tef2\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef2_-300x15.jpg\" width=\"300\" height=\"15\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef2_-300x15.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef2_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Extruded FEP insulated conductors,\u00a0laid parallel and sheathed with an outer jacket of extruded FEP<br \/>\n200\u00b0 C (400\u00b0F)<\/p>\n<p><strong>TEX\/TW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-298\" alt=\"pro.wir.tef3\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef3_-300x9.jpg\" width=\"300\" height=\"9\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef3_-300x9.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef3_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Extruded FEP insulated conductors twisted together<br \/>\n200\u00b0 C (400\u00b0F)<\/p>\n<p><strong>TEX\/SITW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-297\" alt=\"pro.wir.tef4\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef4_-300x12.jpg\" width=\"300\" height=\"12\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef4_-300x12.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef4_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Extruded FEP insulated conductors twisted together and\u00a0sheathed with an outer jacket of silicon rubber<br \/>\n105\u00b0 C (221\u00b0F)<\/p>\n<p><strong>TEX\/CUTEXTW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-296\" alt=\"pro.wir.tef5\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef5_-300x13.jpg\" width=\"300\" height=\"13\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef5_-300x13.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef5_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Extruded FEP insulated conductors twisted together and\u00a0braided with a tinned copper shield.<br \/>\nThe wire is jacketed with extruded FEP<br \/>\n200\u00b0 C (400\u00b0F)<\/p>\n<p><strong>TEX\/GTEXTW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-295\" alt=\"pro.wir.tef6\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef6_-300x13.jpg\" width=\"300\" height=\"13\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef6_-300x13.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef6_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Extruded FEP insulated conductors twisted together and braided with a fiberglass yarn.<br \/>\nThe wire is jacketed with extruded FEP<br \/>\n200\u00b0 C (400\u00b0F)<\/p>\n<p><strong>TFHF\/TW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-294\" alt=\"pro.wir.tef7\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef7_-300x9.jpg\" width=\"300\" height=\"9\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef7_-300x9.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef7_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Twisted construction PTFE under fused Kapton tape insulation<br \/>\n260\u00b0 C (500\u00b0F)<\/p>\n<p><strong>K\/K<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-293\" alt=\"pro.wir.tef8\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef8_-300x9.jpg\" width=\"300\" height=\"9\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef8_-300x9.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef8_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Kapton fused tape insulated cores, laid parallel and\u00a0sheathed with an outer jacket of Kapton<br \/>\n260\u00b0 C (500\u00b0F)<\/p>\n<p><strong>HF\/D<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-292\" alt=\"pro.wir.tef9\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.tef9_-300x9.jpg\" width=\"300\" height=\"9\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef9_-300x9.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.tef9_.jpg 380w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Thin (0.9mm. o.d.) Duowrap construction, with one conductor and\u00a0outer jacket sheathed in Kapton<br \/>\n260\u00b0 C (500\u00b0F)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>TF\/TF Fused PTFE tape insulated conductors,\u00a0laid parallel and jacketed with fused PTFE tape 260\u00b0 C (500\u00b0F) TEX\/TEX Extruded FEP insulated conductors,\u00a0laid parallel and sheathed with an outer jacket of extruded FEP 200\u00b0 C (400\u00b0F) TEX\/TW Extruded FEP insulated conductors twisted together 200\u00b0 C (400\u00b0F) TEX\/SITW Extruded FEP insulated conductors twisted together and\u00a0sheathed with an outer [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2038,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"class_list":["post-2001","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PTFE FEP Kapton - TE Instrumentation<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PTFE FEP Kapton - TE Instrumentation\" \/>\n<meta property=\"og:description\" content=\"TF\/TF Fused PTFE tape insulated conductors,\u00a0laid parallel and jacketed with fused PTFE tape 260\u00b0 C (500\u00b0F) TEX\/TEX Extruded FEP insulated conductors,\u00a0laid parallel and sheathed with an outer jacket of extruded FEP 200\u00b0 C (400\u00b0F) TEX\/TW Extruded FEP insulated conductors twisted together 200\u00b0 C (400\u00b0F) TEX\/SITW Extruded FEP insulated conductors twisted together and\u00a0sheathed with an outer [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/\" \/>\n<meta property=\"og:site_name\" content=\"TE Instrumentation\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-07T21:01:01+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/te-temperature-wire-cable\\\/ptfe-fep-kapton\\\/\",\"url\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/te-temperature-wire-cable\\\/ptfe-fep-kapton\\\/\",\"name\":\"PTFE FEP Kapton - TE Instrumentation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/#website\"},\"datePublished\":\"2014-01-22T10:34:52+00:00\",\"dateModified\":\"2026-05-07T21:01:01+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/te-temperature-wire-cable\\\/ptfe-fep-kapton\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/te-temperature-wire-cable\\\/ptfe-fep-kapton\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/te-temperature-wire-cable\\\/ptfe-fep-kapton\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/home\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"TE Temperature Wire &#038; Cable\",\"item\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/what-we-do\\\/te-temperature-wire-cable\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"PTFE FEP Kapton\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/\",\"name\":\"TE Instrumentation\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/#organization\",\"name\":\"Thermo Electric\",\"url\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/te-instrumentation.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/TE-logo-FINAL.webp\",\"contentUrl\":\"https:\\\/\\\/te-instrumentation.nl\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/TE-logo-FINAL.webp\",\"width\":1000,\"height\":500,\"caption\":\"Thermo Electric\"},\"image\":{\"@id\":\"https:\\\/\\\/te-instrumentation.nl\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PTFE FEP Kapton - TE Instrumentation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/","og_locale":"en_US","og_type":"article","og_title":"PTFE FEP Kapton - TE Instrumentation","og_description":"TF\/TF Fused PTFE tape insulated conductors,\u00a0laid parallel and jacketed with fused PTFE tape 260\u00b0 C (500\u00b0F) TEX\/TEX Extruded FEP insulated conductors,\u00a0laid parallel and sheathed with an outer jacket of extruded FEP 200\u00b0 C (400\u00b0F) TEX\/TW Extruded FEP insulated conductors twisted together 200\u00b0 C (400\u00b0F) TEX\/SITW Extruded FEP insulated conductors twisted together and\u00a0sheathed with an outer [&hellip;]","og_url":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/","og_site_name":"TE Instrumentation","article_modified_time":"2026-05-07T21:01:01+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/","url":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/","name":"PTFE FEP Kapton - TE Instrumentation","isPartOf":{"@id":"https:\/\/te-instrumentation.nl\/en\/#website"},"datePublished":"2014-01-22T10:34:52+00:00","dateModified":"2026-05-07T21:01:01+00:00","breadcrumb":{"@id":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/ptfe-fep-kapton\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/te-instrumentation.nl\/en\/home\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/"},{"@type":"ListItem","position":3,"name":"TE Temperature Wire &#038; Cable","item":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/"},{"@type":"ListItem","position":4,"name":"PTFE FEP Kapton"}]},{"@type":"WebSite","@id":"https:\/\/te-instrumentation.nl\/en\/#website","url":"https:\/\/te-instrumentation.nl\/en\/","name":"TE Instrumentation","description":"","publisher":{"@id":"https:\/\/te-instrumentation.nl\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/te-instrumentation.nl\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/te-instrumentation.nl\/en\/#organization","name":"Thermo Electric","url":"https:\/\/te-instrumentation.nl\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/te-instrumentation.nl\/en\/#\/schema\/logo\/image\/","url":"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2026\/07\/TE-logo-FINAL.webp","contentUrl":"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2026\/07\/TE-logo-FINAL.webp","width":1000,"height":500,"caption":"Thermo Electric"},"image":{"@id":"https:\/\/te-instrumentation.nl\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2001","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/comments?post=2001"}],"version-history":[{"count":2,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2001\/revisions"}],"predecessor-version":[{"id":2310,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2001\/revisions\/2310"}],"up":[{"embeddable":true,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2038"}],"wp:attachment":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/media?parent=2001"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}