{"id":2003,"date":"2014-01-22T09:53:11","date_gmt":"2014-01-22T09:53:11","guid":{"rendered":"https:\/\/te-instrumentation.nl\/pvc\/"},"modified":"2026-05-07T22:01:02","modified_gmt":"2026-05-07T21:01:02","slug":"pvc","status":"publish","type":"page","link":"https:\/\/te-instrumentation.nl\/en\/what-we-do\/te-temperature-wire-cable\/pvc\/","title":{"rendered":"PVC"},"content":{"rendered":"<p><strong>P<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-280\" alt=\"pro.wir.pvc1\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc1_-300x26.jpg\" width=\"300\" height=\"26\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc1_-300x26.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc1_.jpg 380w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>PVC insulated conductors fused together to form a ripcord construction<br \/>\n105\u00b0 C (221\u00b0F)<\/p>\n<p><strong>P\/P<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-281\" alt=\"pro.wir.pvc2\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc2_-300x16.jpg\" width=\"300\" height=\"16\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc2_-300x16.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc2_.jpg 380w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>PVC insulated conductors, laid parallel and sheathed with an outer jacket of PVC<br \/>\n105\u00b0 C (221\u00b0F)<\/p>\n<p><strong>P\/PTW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-282\" alt=\"pro.wir.pvc3\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc3_-300x12.jpg\" width=\"300\" height=\"12\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc3_-300x12.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc3_.jpg 380w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>PVC insulated conductors, twin twisted together and helically wrapped with aluminium backed mylar tape. A tinned copper drain wire is in contact with the aluminium tape.<\/p>\n<p>The wire is sheathed with an outer jacket of PVC<br \/>\n90\u00b0 C (194\u00b0F)<\/p>\n<p><strong>P\/ALPTW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-286\" alt=\"pro.wir.pvc4\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc4_-300x20.jpg\" width=\"300\" height=\"20\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc4_-300x20.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc4_.jpg 380w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>PVC insulated conductors, twin twisted together and helically wrapped with aluminium backed mylar tape. A tinned copper drain wire is in contact with the aluminium tape.<\/p>\n<p>The wire is sheathed with an outer jacket of PVC<br \/>\n105\u00b0 C (221\u00b0F)<\/p>\n<p><strong>P\/CUPTW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-283\" alt=\"pro.wir.pvc5\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc5_-300x22.jpg\" width=\"300\" height=\"22\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc5_-300x22.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc5_.jpg 380w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>PVC insulated conductors, twin twisted together with a tinned copper overbraid and outer PVC jacket<br \/>\n90\u00b0 C (194\u00b0F)<\/p>\n<p><strong>P\/ALPWPTW<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-284\" alt=\"pro.wir.pvc6\" src=\"\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc6_-300x22.jpg\" width=\"300\" height=\"22\" srcset=\"https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc6_-300x22.jpg 300w, https:\/\/te-instrumentation.nl\/wp-content\/uploads\/2014\/01\/pro.wir_.pvc6_.jpg 380w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><span>PVC insulated conductors with aluminium tape screen, drainwire, PVC inner jacket, galvanised steel wire armour and PVC outer jacket<br \/>\n105\u00b0 C (221\u00b0F)<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>P PVC insulated conductors fused together to form a ripcord construction 105\u00b0 C (221\u00b0F) P\/P PVC insulated conductors, laid parallel and sheathed with an outer jacket of PVC 105\u00b0 C (221\u00b0F) P\/PTW PVC insulated conductors, twin twisted together and helically wrapped with aluminium backed mylar tape. A tinned copper drain wire is in contact with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2038,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"class_list":["post-2003","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2003"}],"collection":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/comments?post=2003"}],"version-history":[{"count":2,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2003\/revisions"}],"predecessor-version":[{"id":2311,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2003\/revisions\/2311"}],"up":[{"embeddable":true,"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/pages\/2038"}],"wp:attachment":[{"href":"https:\/\/te-instrumentation.nl\/en\/wp-json\/wp\/v2\/media?parent=2003"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}